User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics
Cold-start capable
Provides temporary battery power when the utility power is out
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection
High online efficiency
Reduces utility costs, generates less heat
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
SmartSlot
Customize UPS capabilities with management cards
Energy meter
Provides actual kilowatt hours of usage for energy conscious users
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
Scalable runtime
Allows additional run time to be quickly added as needed
Network manageable
Provides remote power management of the UPS over the network
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models)
Serial connectivity
Provides management of the UPS via a serial port
Disconnected battery notification
Warns when a battery is not available to provide backup power
USB connectivity
Provides management of the UPS via a USB port (not available on all models)
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
Auto recognition of external batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment
Load shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups)
Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs
Multiple switched outlet groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding
High frequency design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling
Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups)
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement
LED Indicators
Provide easy-to-read status of the unit and utility power conditions
Wide input voltage range
Designed for harsh electrical environments to save battery life
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery
Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert
User-replaceable batteries
Audible alarms
Automatic self-test
Intelligent battery management
Pure sine wave output on battery
Cold-start capable
Temperature-compensated battery charging
Green mode
High online efficiency
Intuitive LCD interface
Predictive replace battery date
SmartSlot
Energy meter
Battery failure notification
Safety-agency approved
Scalable runtime
Network manageable
Hot-swappable batteries
Boost and Trim Automatic Voltage Regulation (AVR)
Serial connectivity
Disconnected battery notification
USB connectivity
Adjustable voltage-transfer points
Adjustable voltage sensitivity
Auto recognition of external batteries
Automatic restart of loads after UPS shutdown
Rack/Tower convertible
Load shedding
Sequenced network shutdown and reboot
Multiple switched outlet groups
High frequency design
Outlet group control
Predicitive failure notification
LED Indicators
Wide input voltage range
Frequency and voltage regulation
Overload protection
Power conditioning
StruxureWare Data Center Expert compatible
Intuitive LCD interface provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
High frequency design reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
APC Smart-UPS X 2000 Rack/Tower LCD recognizes when external battery packs are attached and automatically adjusts runtime.
Patent-pending operating mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Battery
Spec | Value |
---|---|
Quantity | 1 |
Technology | Lead acid |
Run Time (Up To) | 11 min at full load ¦ 27.6 min at half load |
Recharge Time | 3 hours |
Dimensions & Weight
Spec | Value |
---|---|
Width | 17 in |
Depth | 26.3 in |
Height | 3.3 in |
Weight | 84.88 lbs |
Dimensions & Weight (Shipping)
Spec | Value |
---|---|
Shipping Width | 23.5 in |
Shipping Depth | 34.2 in |
Shipping Height | 9.6 in |
Shipping Weight | 100.09 lbs |
Environmental Parameters
Spec | Value |
---|---|
Min Operating Temperature | 32 °F |
Max Operating Temperature | 104 °F |
Humidity Range Operating | 0 - 95% |
Sound Emission | 55 dBA |
Expansion / Connectivity
Spec | Value |
---|---|
Interfaces | 1 x USB ¦ 1 x serial ¦ 1 x EPO (emergency power off) |
Expansion Slots | 1 (total) / 1 (free) x SmartSlot |
General
Spec | Value |
---|---|
Device Type | UPS - external |
Height (Rack Units) | 2U |
Color | Black |
Manufacturer Warranty
Spec | Value |
---|---|
Service & Support | Limited warranty - 3 years ¦ Limited warranty - batteries - 2 years |
Miscellaneous
Spec | Value |
---|---|
Cables Included | Serial cable ¦ USB cable ¦ Power cable - integrated - 8 ft |
Rack Mounting Kit | Included |
Features | Audible alarm, LCD display, Automatic Voltage Regulation (AVR), LED indicators, overload protection, cold-start function |
Compliant Standards | FCC Class A certified, CSA, TUV, BSMI, NOM, UL 1778, VCCI Class A ITE, EN55022 Class A, FCC Part 15, EN 50091-2, RoHS Exemption 7b, REACH |
Networking
Spec | Value |
---|---|
Remote Management Interface | RS-232, USB |
Power Device
Spec | Value |
---|---|
UPS Technology | Line interactive |
Input Voltage | AC 120 V |
Input Voltage Range | AC 82 - 147 V |
Input Voltage Range (Adjustable) | AC 75 - 154 V |
Frequency Provided | 47 - 53 / 57-63 Hz |
Frequency Required | 50/60 Hz |
Input Connectors | Power NEMA 5-20 |
Power Output Connectors Details | 3 x power NEMA 5-15 ¦ 3 x power NEMA 5-20 ¦ 1 x power NEMA L5-20 |
Output Voltage | 120 V 47 - 53 / 57-63 Hz |
Power Capacity | 1.8 kW / 1920 VA |
Output Waveform | Sinewave |
Surge Suppression | Yes |
Surge Energy Rating | 540 Joules |
Software / System Requirements
Spec | Value |
---|---|
Software Included | Drivers & Utilities |
Higher ED | K-12 | Other | |
---|---|---|---|
Alabama | Available | Available | Available |
Alaska | Available | Available | Available |
Arizona | Available | Available | Available |
Arkansas | Available | Available | Available |
California | Available | Available | Available |
Colorado | Available | Available | Available |
Connecticut | Available | Available | Available |
Delaware | Available | Available | Available |
District of Columbia | Available | Available | Available |
Florida | Available | Available | Available |
Georgia | Available | Available | Available |
Hawaii | Available | Available | Available |
Idaho | Available | Available | Available |
Illinois | Available | Available | Available |
Indiana | Available | Available | Available |
Iowa | Available | Available | Available |
Kansas | Available | Available | Available |
Kentucky | Available | Available | Available |
Louisiana | Available | Available | Available |
Maine | Available | Available | Available |
Maryland | Available | Available | Available |
Massachusetts | Available | Available | Available |
Michigan | Available | Available | Available |
Minnesota | Available | Available | Available |
Mississippi | Available | Available | Available |
Missouri | Available | Available | Available |
Montana | Available | Available | Available |
Nebraska | Available | Available | Available |
Nevada | Available | Available | Available |
New Hampshire | Available | Available | Available |
New Jersey | Available | Available | Available |
New Mexico | Available | Available | Available |
New York | Available | Available | Available |
North Carolina | Available | Available | Available |
North Dakota | Available | Available | Available |
Ohio | Available | Available | Available |
Oklahoma | Available | Available | Available |
Oregon | Available | Available | Available |
Pennsylvania | Available | Available | Available |
Rhode Island | Available | Available | Available |
South Carolina | Available | Available | Available |
South Dakota | Available | Available | Available |
Tennessee | Available | Available | Available |
Texas | Available | Available | Available |
Utah | Available | Available | Available |
Vermont | Available | Available | Available |
Virginia | Available | Available | Available |
Washington | Available | Available | Available |
West Virginia | Available | Available | Available |
Wisconsin | Available | Available | Available |
Wyoming | Available | Available | Available |